SKF 18SB1037 Rebuild With Tight Run Out Specifications



CHALLENGE

Possible cause of failure: Catastrophic failure of front roller bearing likely due to friction from excessive lubrication. Multiple types of grease found throughout the spindle, and the grease was not contained to rolling elements. Customer indicated that front roller preload must not allow more than .0002'' axial movement @1000lbs vertical pressure. Front 90mm shaft pilot OD undersized -12/-15µ with runout of 4/5µ, customer stated that this is not significant.

SOLUTION

Recommended action: Clean, inspect overall dimensions. Replace bearings, screws, drive coupling bushings, grease fittings & dust covers. Adjust roller preload per customer spec, balance, assemble and break in. Final quality control inspection.

Does your spindle need repair? GET A QUOTE TODAY

More Case Studies

Repair History - Here are examples of similar spindle repairs that may contain additional information that will help you. If you have additional questions, please contact us.